Support Issue 100 series
iGrow 100 Series Irrigation
In order to water multiple times with your iGrow800 controller, you would have to manipulate the Humidity Settings in order to achieve this Goal. Please follow the steps in sequence to obtain multiple watering’s within a 24 hour period, and if you ...
iGrow 100 Series Sensor Troubleshooting Video
Click the link below for information on troubleshooting the iGrow 100 series sensor.
iGrow 100 - Memory Corruption Issue
MEMORY CORRUPTED 1st Format File System Process Menu->SystemSetup->6. Advanced-> More->button 3 for Clear Data->Format file system (button 2) This will remove all webserver files. 2nd Check AC out outlet (make sure its 110) 3rd Check DC from power ...
***** iGrow Sensor Info, Issues and Troubleshooting
iGrow 100 series Sensor Issues Outdoor/Indoor Temp/Hum Sensor Troubleshooting Temperature sensor not registering. Check sensor connection wires on the controller to make sure there tight and securely fastened. Check connections inside junction box ...
iGrow 400 Communications Information
To wire your Controller for LinkConn 100 Software, you would do the following: After you have Hardwired your Installation, you must program the controller and the PC to communicate FROM THE CONTROLLER SystemSetup>Communication Setup>MODBUS In Modbus ...
iGrow 800 Alarm & Face Separation Issues
Please take the following steps to format file system 1st SAVE EXISTING CONFIGURATION SETTINGS (set points/equipment settings/stages). To save your configuration you would do the following: Insert USB stick into controller Press OK-> ...
Alarm Setup on Controller and Notifications with LinkConn
You can set an output on your iGrow 800 to be an Alarm Watch this video link to get an understanding of The Alarm Output and how to program You can also receive phone alerts with the Link Conn Software as well
iGrow 800 Alarm Options
In order to set up one of your outputs to be an ALARM, you would need to take the following steps: On the controller you would press OK->SystemSetup->Equipment Setup-> on the equipment menu you want to choose an output to be an alarm OK-> Then under ...
iGrow 100 Analog Probe Wiring & Progamming
Please download the attached 100 Series Analog Probe Installation & Programming guide.
iGrow 800 Analog Sensor Troubleshooting
Please take the following steps in troubleshooting your Temperature Probe. iGrow 100 Series Sensor Troubleshooting Temperature sensor is fluctuating or not registering at all Check sensor connection wires on the controller make sure there snug & ...
iGrow 800 Checking Continuity & Repair Address
Here is the Video Link on Checking Continuity with your iGrow 800 Controller iGrow 100 Series Checking Continuity As for the Repair, you can send the controller in, and our factory can run tests to determine reasons behind the buttons not working. ...
iGrow 800 Clock Issue
If you have Clock Issue, it means your firmware on your controller is outdated, and what you need to do an update. First, save your existing settings (setpoints/equipment/stages) we would have to save your configurations first. To save your ...
iGrow 100 Series Communication Options
With your iGrow 100 Series Controllers you can view your controllers with Software, the Web Browser from you home Network, or the iGrow Cloud. You would need a Communications module to establish. Please view our Demo cloud to get an idea, of how your ...
iGrow 800 Communications with Computer
VCM and VCS VCM - Must have I control | has to be running on a PC | then use Remote Desktop to access icontrol from a different PC. (team viewer, net viewer, web ex) VCS – (not cloud) allows you to access controller from a Browser Enabled Device. ...
iGrow 800 Configuration Setup
The Configuration File .icf is a special file format that only the controller’s Logic can recognize. This file is to be set aside for safekeeping for backup purposes just in case. To restore this configuration, or to save new configurations that you ...
iGrow 800 to PC Hardwiring & Software Download Links
Here is the Link to download your Software – LinkConn 100, as well as attachments that will provide a visual understanding on how to hardwire your Equipment to PC. LinkComm 100 download ...
iGrow 800 Start Up Information
Attached is an iGrow800 Manual, iDrive 300 Manual, wiring diagram for your Temperature & Humidity Senso
iGrow 800 Curtain programming and troubleshooting
Here is a video link for Curtain Programming iGrow 100 Series Curtain Programming What's real important on your Curtain programming are the times you input into the programming Make sure the open to close time is correct and imputed in the ...
iGrow 800 Digi Extend Setup - MaxStream
The Serial Loopback Adapter configures Radio2 to function as a repeater by looping data back into the module for retransmission The Null Modem swaps The RX and The TX The 3 wire Pigtail is utilized for RS232 (1000 Series COMM) The 2 wire pigtail is ...
iGrow 800 Expansion Board Information
Please view the following Video Link that will provide much information on the Expansion Board. iGrow 800 with The Expansion Board
iGrow 800 Frozen State
Please follow the below instructions to resolve the Frozen iPonic State that you are experiencing CREATE A FOLDER ON YOUR DESKTOP AND NAME IT PRG INSERT THE 2 ATTACHED FILES zz INTO THE NEWLY CREATED FOLDER PRG ON A BLANK USB INSERT THE PRG FOLDER ...
iGrow 800 Heat, Bump Feature, and Web File Questions
Regarding your heat, you would have to set it on AUTO to respond to programming. (Temp Staging, Overrides, DEHUM Staging) OFF its Shut OFF period and will not respond to Auto Programming. Check the TOGGLE SWITH ON THE BACK OF THE PC AND MAKE SURE IT ...
iGrow 800 Sensor Jumping issues
Please take the following steps in troubleshooting your Temperature Probe. · iGrow 100 Series Sensor Troubleshooting - Check connection’s inside junction box (if one exists) for moisture or corrosion - Check the PCB for corrosion, moisture or ...
iGrow 800 Light programming
In order to have your lights to turn on from 3pm to 6pm you would do a 3hr override. Watch the following video link to program equip overrides.
iControl Web Based Software
In regards to your question on viewing the controller from a web browser The 1000 series Controllers are software viewable only The 100 series Controllers (iGrow 400 & 800) give you the option to view it from the following views VCM and VCS VCM - ...
Wireless Accesss for the 100 series controller
To establish communications between your iGrow800 series controllers to you PC you have 3 options: · You can “Hard Wire” the links · You can use “Wireless Radios” in which you would have to have 2 wireless radios to make this operational · You can ...
iGrow 800 VCS Network Connnectivity Troubleshooting
*****WITH THE iGrow 800 CONTROLLER’S POWER UNPLUGGED****** a. Please check and see if the Communications Module is properly seated on the circuit board *****WITH THE IGROW 800 CONTROLLER’S POWER ON***** b. Check and see if the Communications Module ...
iGrow 800 Programming Information
Please view the following videos in the order that there in, so you can program your controller with confidence, and also have an understanding of what Setpoints are for, Staging of your equipment in Temperature and Humidity Stages, as well as how to ...
iGrow 800 Relay Info and Wiring Examples
Control Relays & Contactors Your iGrow Series 100™ has 4 or 8 output relays that are provided as dry contacts, i.e. switch closures. If an output is activated to ON, the switch is “closed” (shorted); and if it iis activated to OFF, the switch is ...
iGrow 800 Start Up Videos
Please view the following videos in the order that there in, so you can program your controller with confidence, and also have an understanding of what Setpoints are for, Staging of your equipment in Temperature and Humidity Stages, as well as how to ...
iGrow 800 Troubleshooting Sensor and Start Up Videos
Please view the following videos in the order that they're in, so you can troubleshoot your sensor fluctuating issues, as well as program your controller with confidence, You will develop an understanding on what Setpoints are for, Staging of your ...
iGrow 800 Startup Video Links and Manual
Please view the following videos in the order that there in, so you can program your controller with confidence, and also have an understanding of what Setpoints are for, Staging of your equipment in Temperature and Humidity Stages, as well as how to ...
iGrow 800 Wiping Controller & Repair Options
If the firmware update does not resolve the Random Freezing of the Screen, please take the following steps to format file system (A) SAVE EXISTING CONFIGURATION SETTINGS (set points/equipment settings/stages). To save your configuration you would do ...
iGrow 800 Wiring questions
You want to use 24 Gauge Shielded Standard Wire for your RS 485 Network. In regards to the Link Cloud, that is currently unavailable with this controller. If you are going to use Linkconn 100 software, make sure you download the drivers for your USB ...
iGrow 800 Temp Probe Fluctuating issues
Please take the following steps in troubleshooting your Temperature Probe. · iGrow 100 Series Sensor Troubleshooting Check connection’s inside junction box (if one exists) for moisture or corrosion Check the PCB for corrosion, moisture or ...
iGrow 800 Sensor Failure Issues
Please view the following troubleshooting steps and see if they resolve the Sensor Issue associated with Sensor Failure. · Check sensor connection wires on the controller make sure there snug & tight. · Check connection’s inside junction box (if one ...
iGrow 100 Digital Temp & Humidity Sensor Troubleshooting
Please view the following troubleshooting steps and see if they resolve the Sensor Issue which is not giving a steady reading · Check sensor connection wires on the controller make sure there snug & tight. · Check connection’s inside junction box (if ...
iGrow 800 Sensor Issues
If your sensor issues persist, please view the following video link to assist you in troubleshooting your sensor issues.
iGrow 800 Weather Station Network Troubleshooting
What we need do is use deductive reasoning in isolating the issue and find the problem that is causing the Communication Breakdown. · Check 12V power supply (is it rigid) it could be marginal, and could be pushed to the edge, this could in fact be ...