iGrow 100 Digital Temp & Humidity Sensor Troubleshooting
iGrow 100 Digital Temp & Humidity Sensor Troubleshooting
Please view the following troubleshooting steps and see if they resolve the Sensor Issue which is not giving a steady reading
·Check sensor connection wires on the controller make sure there snug & tight.
·Check connection’s inside junction box (if one exists) for moisture or corrosion
·Check the PCB for corrosion, moisture or contamination build up.
·Check the line that leads to that box for cuts or any damage which will affect the sensors readings.
·Check for wire any interference sources (voltage, motors, inverters, etc….)
·Cycle equipment ON and OFF and see if Sensor Reading appears or Stabilizes
Check Sensor MAPPING (In Temp & Humidity)
Measure the Power Supply Cube and make sure its 12VDC – you can even try switching the Cubes with another controller to determine if it’s in fact the Cube.
Please view our sensor troubleshooting video as well.
THIS PRODUCT HAS BEEN DISCONTINUED AND REPLACED BY THE PEARL CONTROL SYSTEM. https://link4controls.com/link4_controllers/ If your Digital Temperature and Humidity Sensor is displaying wrong readings, spiking up and down or not reading at all its time ...
iGrow 100 series Sensor Issues Outdoor/Indoor Temp/Hum Sensor Troubleshooting Temperature sensor not registering. Check sensor connection wires on the controller to make sure there tight and securely fastened. Check connections inside junction box ...
Attached is the iGrow 1800 User Manual Also here is a list of video links to assist you in obtaining a General understanding of how to program the iGrow1800 controller.
The iDoser represents the latest in nutrient control technology. It interfaces the iGrow 1800 for local programming and control and consists of up to eight injectors feeding a manifold where the nutrients and/or acid/base are injected into the water ...