iGrow 100 series Sensor Issues 

Outdoor/Indoor Temp/Hum Sensor Troubleshooting

 

Temperature sensor not registering.

  • Check sensor connection wires on the controller to make sure there tight and securely fastened.
  • Check connections inside junction box (if one exists), for moisture or corrosion.
  • Check the PCB for corrosion, moisture or contamination build up.
  • Check the line that leads to that box for cuts or any damage which will affect the sensors readings.
  • Check for wire any interference sources (voltage, motors, inverters, etc….)
  • Check Sensor Mapping
  • Check Calibrated Inputs

 

Inside Temperature Sensor Failure

  •       Probe comes with the 100 series, the temp humidity is an additional cost.
  •       Probe (Analog) Temp/Hum(Digital) Mapping is Vital
  •       Probe has to be installed at the inside temp sensor location and mapped to analog 1.

 

“ 1 “ INSIDE TEMP SENSOR ONLY ( for 100 series controllers)

  • You can assign an additional sensor to be backup or outside, but only 1 inside.

 

Sensor Cable Length Digital

  • 100ft cable

Sensor Cable Length Analog

  • 50ft

Max length for signal quality 150ft

  • Must have shielded cable
  • Away from electrical current
  • Test the reading with portable temp device and just calibrate

 

Can I install the temperature sensor on a different channel?

  • Analog | or Digital sensor locations on the PCB board
  • You can as long as you map the sensor to  where you put it..

 

Temperature Sensor (PROBE) Installation 100 series

  • 1 Pair 2 wires Alum color Copper color
  • Non polarity wires - does not matter which output
  • AIN1 & GND is the location ( 3 screw blue T.B. on PCB  “Inside Temperature Sensor”)

 

Can I get 2 separate temp readings on a big greenhouse one for each side using 2 temp sensors?

YES

  • Average – up to 4 temp locations within the greenhouse, but this will only be the average.
  • You can also install a separate temp sensor, but you would connect to the outside temp location and the screen would display “Outside Temp”.

 

With 2 temp sensors within the greenhouse, can I run 1 furnace off a) sensor and 1 of b) sensor?

  • NO – Only the 1000 series can support this.
  • Another alternate option is to purchase another 400 to be used as a thermostat.