Please view the following troubleshooting steps and see if they resolve the Sensor Issue associated with Sensor Failure.
·Check sensor connection wires on the controller make sure there snug & tight.
·Check connection’s inside junction box (if one exists) for moisture or corrosion
·Check the PCB for corrosion, moisture or contamination build up.
·Check the line that leads to that box for cuts or any damage which will affect the sensors readings.
·Check for wire any interference sources (voltage, motors, inverters, etc….)
·Cycle equipment ON and OFF and see if Sensor Reading appears or Stabilizes
Check Sensor MAPPING (In Temp & Humidity)
Measure the Power Supply Cube and make sure its 12VDC – you can even try switching the Cubes with another controller to determine if it’s in fact the Cube.
Please view our sensor troubleshooting video as well.
iGrow 100 series Sensor Issues Outdoor/Indoor Temp/Hum Sensor Troubleshooting Temperature sensor not registering. Check sensor connection wires on the controller to make sure there tight and securely fastened. Check connections inside junction box ...
Please take the following steps in troubleshooting your Temperature Probe. · iGrow 100 Series Sensor Troubleshooting - Check connection’s inside junction box (if one exists) for moisture or corrosion - Check the PCB for corrosion, moisture or ...
Please view the following videos in the order that they're in, so you can troubleshoot your sensor fluctuating issues, as well as program your controller with confidence, You will develop an understanding on what Setpoints are for, Staging of your ...
Please View the following Method in Installing the Stand Alone Rain Sensor to the iGrow 400/800 Controller. Attached to this Article is a Rain Sensor Manual, and here is a video link on installing and mapping the Rain Sensor to the controller.