Daisy Chaining iDrive 150 DCP
Can the iDrive 150DCP be daisy chained like the 300M’s? The answer is yes, but you still need to remove the 24V and COM from the slave iDrive PCB.
iDrive Troubleshooting
iDrive (* 1 iDrive per motor*) The iGROW is just dry switching contacts that the iDrive receives. Master into a Slave On the J2 PCB #3  (to 24VAC transformer) remove and INDEPENDENTLY cap off. Slave - Make into a Slave J1 on circut board (9 - 10 ...
iDrive 300 to iGrow 1400
Click for information for the iDrive 300 to the iGrow 1400.
iDrive 300 - Thermal Overload Testing
If your iDrive 300 Thermal Overload is always tripping it is time to look at a few things. Compare the Motor Running Current Draw with the Size of the Thermal Overload that came with the iDrive Most AC Motors have on there Motor Spindle a Plate that ...
Connecting an iDrive with a Thermostat
IDRIVE – to - THERMOSTAT To wire the iDrive to a Thermostat, it would have to be a two-stage low voltage thermostat that can dry switch the OPEN, CLOSE and COMMON (J1 1/2/3) Terminals on the Master iDrive based on a temperature setting. You would ...