Support Issue 1000 series
iGrow 1000 Series - Memory Corruption
MEMORY CORRUPTED 1st Format File System Process Menu->SystemSetup->6. Advanced-> More->button 3 for Clear Data->Format file system (button 2) This will remove all webserver files. 2nd Check AC out outlet (make sure its 110) 3rd Check DC from power ...
1000 Series Communication Issues
If the SM can’t see Zone Master, it could be a: · Wiring · Programming · Chip Issue On the Comm Diag Screen on the Site Master, are Zone 2 & 3 Displaying 3’s on the 1st column, 3 represents successful communication within the network. Please get the ...
1000 Series Communication and Sensor Mapping
You have to make sure that your communications on your Controller network is set correctly. For your network (1 1600 & 2 1400) you have to determine how its going to be mapped: 1 site master 2 slaves 1 site master 1 Zone Master 1 Slave 1 Site master, ...
Heat and Cool Demand Understanding
Heat Demand One of the iGrow1600’s advanced features is Heat Demand, predictive control. This feature helps you optimize the efficiency of your greenhouse while reducing equipment usage by changing more gradually rather than by waiting until ...
Wiring 24 Solenoids off of iGrow 1400 & Link 4 Standard Panel 970-3000-02
Attach 1 side of solenoid to the + of the Output and the other side of solenoid you would wire to the Common that is in the Panel Box NOTE: The 24V Transformer in the Panel sustains a total of 40VA The Contactor Energized equipment consumes 30VA ...
iGrow 1000 Viewing Multiple Controllers at one time
iGrow1000Series Networking Multiple Controllers If you have previously been able to see multiple controllers and can no longer do so, please create your support request below and we will contact you shortly.