iPonic CO2 Issues
Co2 Sensor Failure and Freezing
- Check Firmware Version is up to date
CO2 Sensor Failing to Meet PPM Setpoint (EXAMPLE: CO2 Setpoint 1400 / Reading 1200 CO2 not ON!)
- What channel is the light connected to? Does that channel turn on?
- The CO2 may not turn on when the light is off.
- Need Configuration File
Forced On?|Deadband?|Cycle?|Calibration(raw/cal/adj)|Map|firmware|format system| Restore Fact Defaults
- Has calibration been altered from the default settings?
- Has the sensor ever been replaced?
- Are there variations in TEMP & HUM readings?
- Is the clock set correctly?
- The light settings should be set to turn on with the day setpoint period.
- Check the Day and Night setpoint start times from the setpoint screen in the menus.
- Make sure that the Firmware is 1.8.1.0.
Note: Original device must be returned in order for the RMA ticket to be processed successfully.
Map Individual Sensors (iPonic)
- Menu->SystemSetup->SensorSetup->Button 2 for Advanced->Button 1 to choose sensor to map
Calibrate Individual Sensors (iPonic)
Menu->SystemSetup->SensorSetup->Button 2 for Advanced->Button 2 to calibrate by entering adjustment value