Temperature Drive to Average Control
Drive to Average will adjust the night setpoints so as to maintain an overall daily average target temperature.
Here is a Video:
To program hit Enter/Menu-> then highlight Setpoints Advance hit Enter/Menu -> then highlight Drive To Average and hit Enter/Menu.
Selecting Drive to Average brings you to the following screen
The Drive to Average option can be either Enabled or Disabled. Enabling it engages the option. The Target Temp is the average temperature you are trying to achieve. The Max Fail Days is the number of successive days that the target temperature cannot be achieved after which adjustments are made automatically to the day setpoints.
The Allowable Target Deviation is the number of degrees that the average temperature is allowed to vary from the setpoint before a fail day is signified. The Max Adjustment Size is the maximum number of degrees by which a setpoint adjustment can be made.
Here is a view of Setpoint Advance Influence Factors Programming with LinkConn 1800 Software which provides a more simpler control view.
For detailed instructions and important information on the Pearl Control System, please refer to the attached manual. It contains everything you'll need to get started and use the control system effectively. Edit: Version 1.17.18 Manual Attached.
Please view the following videos in the order that there in, so you can program your controller with confidence, and also have an understanding of what Setpoints are for, Staging of your equipment in Temperature and Humidity Stages, as well as how to ...
Attached is the iGrow 1800 User Manual Also here is a list of video links to assist you in obtaining a General understanding of how to program the iGrow1800 controller.