iGrow 800 - VCM and VCS Issues

iGrow 800 - VCM and VCS Issues

VCM and VCS

 

VCM - Must have the LinkConn software installed | has to be running on a PC | use Remote Desktop to access LinkConn from a different PC. (team viewer, netviewer, web ex)

VCS – (not cloud) Allows you to access controller from a Browser Enabled Device. WITHIN THE NETWORK!

  • You would type in the IP of the controller in browser address line which would allow you to see it.
  • The Webpage displayed shows Front View of Controller – fully functional with mouse cursor.
    • Example on Company’s Network IP address 192.168.50.240

 

VCM

VCS

  • LinkConn
  • NO LinkConn
  • No Web Browser
  • Web Browser
  • Can remote in Via Team viewer or Web Ex and see your LinkConn Software Via the desktop From iPhone
  • Cannot Remote in to see LinkConn Software

 

Converting VCM to VCS

This is the process of changing your controller from VCM to VCS.

Save existing settings and restore them after conversion because you will lose the settings in the process. See SAVING/DOWNLOADING CONFIGURATION  Settings

  • Contact Support for the firmware download
  • After downloading the file, create a folder named PRG, and then put the firmware into the folder
  • Insert the USB stick into controller, and follow provided instructions to upgrade.

OK> System Setup> Advance>6.BeginBootload  (then you will see a couple of pop up screens)

Default setting “NO” | Begin bootload “Yes” | Ok to Confirm

  • Please watch this video to assist you as well.

    • Related Articles

    • iGrow 800 Sensor Issues

      If your sensor issues persist, please view the following video link to assist you in troubleshooting your sensor issues.
    • iGrow 100 LinkConn Issues

      100 Series LinkConn Issues My LinkConn Software cannot see my controller. SystemSetup>CommunicationSetup>MODBUS In Modbus settings Modbus communication: Remote or Broadcast Modbus address: 1 – 242 if you have more than one controller use different ...
    • ***** iGrow Sensor Info, Issues and Troubleshooting

      iGrow 100 series Sensor Issues Outdoor/Indoor Temp/Hum Sensor Troubleshooting Temperature sensor not registering. Check sensor connection wires on the controller to make sure there tight and securely fastened. Check connections inside junction box ...
    • *1000 Series Port Issues

      1000 Series Port Issues Greyed Out – In LinkConn, the iGrow is completely greyed out. Check the Com Port for any changes. USB to Serial Converter - Will omit problems with on board serial ports & Windows com port drivers. When you plug the USB to ...
    • iGrow 800 VCS Network Connnectivity Troubleshooting

      *****WITH THE iGrow 800 CONTROLLER’S POWER UNPLUGGED****** a. Please check and see if the Communications Module is properly seated on the circuit board *****WITH THE IGROW 800 CONTROLLER’S POWER ON***** b. Check and see if the Communications Module ...